Read the standard, not only this summary: 29 CFR 1926.51, Sanitation.
The rule applies to construction employment OSHA covers. Some states run their own plan and can be stricter. California does. Private-sector construction in Texas is under federal OSHA. If you are in San Diego or Los Angeles, Cal/OSHA is part of the job even when this page is quoting the federal table. This page does not restate a state code section it has not quoted.
Table D-1
1926.51(c)(1) says toilets shall be provided for employees according to this table:
| Number of employees | Minimum number of facilities |
|---|---|
| 20 or less | 1 |
| 20 or more | 1 toilet seat and 1 urinal per 40 workers |
| 200 or more | 1 toilet seat and 1 urinal per 50 workers |
The calculator applies the rows this way:
- 1 to 20 employees: the first row, one facility. Urinals are not a separate line on that row.
- 21 to 199: one toilet seat and one urinal per 40 workers, rounded up.
- 200 or more: one toilet seat and one urinal per 50 workers, rounded up.
At exactly 20, the table names both the first row and the start of the second. The calculator stays on the first row. One per 40 at 20 workers would still be a single seat, plus a urinal.
At 200 the ratio changes, and a strict reading can go down. 199 workers are 5 seats and 5 urinals. 200 workers are 4 and 4. The table is a minimum. Crossing 200 is not a reason to haul a unit off the site.
1926.51(c)(2) adds that under temporary field conditions, at least one toilet facility has to be available.
1926.51(c)(4) says the toilet requirements in paragraph (c) do not apply to mobile crews that have transportation readily available to nearby toilet facilities. “Nearby” and “readily available” are facts about the crew, not a slogan. If the crew cannot actually get there, do not treat the exception as met.
What kind of toilet counts
Where the jobsite has no sanitary sewer, 1926.51(c)(3) says one of the following shall be provided unless local codes prohibit it:
- Privies, where their use will not contaminate ground or surface water
- Chemical toilets
- Recirculating toilets
- Combustion toilets
A standard construction porta potty is the chemical-toilet case. A trailer with a holding tank is a conversation with the supplier about which of those categories they are renting you, and about local code. This page will not relabel a product the manufacturer has not described.
A seat and a urinal are both in the sentence
For 21 or more workers, the table says “1 toilet seat and 1 urinal,” not “1 toilet.” Many single units are built with both a seat and a urinal. Whether that one box satisfies both numbers is a question for the company renting it and for the person responsible for the safety plan. The calculator prints both numbers so the quote can be checked against the table. It does not collapse them into one unit on its own.
Drinking water
1926.51(a) is separate from the toilet count, and jobsites miss it:
- An adequate supply of potable water in all places of employment.
- Portable containers that can be tightly closed, with a tap. Water shall not be dipped from containers.
- Containers clearly marked as drinking water, and not used for anything else.
- No common drinking cup. If single-use cups are supplied, provide a sanitary container for the clean cups and a receptacle for the used ones.
Potable water, in the standard, means water that meets the drinking-water standards of the state or local authority, or the EPA’s National Primary Drinking Water Regulations.
1926.51(b) says nonpotable outlets, such as water for industrial or firefighting use only, have to be marked so nobody drinks, washes, or cooks with that water, and that potable and nonpotable systems are not cross-connected.
Washing
1926.51(f)(1) says the employer shall provide adequate washing facilities for employees applying paints, coatings, herbicides, or insecticides, or doing other work where contaminants may be harmful. Those facilities have to be near the work and equipped so employees can remove the substance.
1926.51(f)(3) then sets lavatory rules for places of employment generally. The mobile-crew exception is narrower than people assume: it applies when employees have transportation readily available to nearby washing facilities that meet the same paragraph. Where lavatories are required, each one has hot and cold running water, or tepid running water, plus hand soap or a similar cleanser, and individual hand towels, a blower, or clean sections of cloth toweling.
A bottle of hand sanitizer on a stake is useful. It is not what (f)(3) describes. When you order, ask whether the handwash station is running water with soap and towels, and whether the water is heated or tepid. If the crew is handling coatings or chemicals, point 1926.51(f)(1) at the quote and ask where the washing setup will sit relative to the work.
Showers are a further requirement only when a particular standard requires them. When they are required, 1926.51(f)(4) calls for one shower for each 10 employees of each sex, or fraction, who must shower during the same shift, with soap, hot and cold water through a common discharge, and individual clean towels.
Food, and keeping the unit usable
1926.51(g) says no employee shall be allowed to consume food or beverages in a toilet room or in any area exposed to a toxic material.
The toilet section does not say “service every seven days.” A unit that is full, without paper, or impossible to enter is not meeting the point of the rule even if the headcount matched Table D-1 on delivery day. United Rentals’ sanitation pages, linked from the city listings, describe once-a-week service on long-term rentals and say more frequent visits can be arranged. That is their offer, not an OSHA interval. In hot weather, ask for a shorter cycle and get it on the work order.
ADA on a jobsite is not the event rule
The 2010 ADA Standards, section 203.2, say structures and sites directly associated with the actual processes of construction do not have to comply with those standards or be on an accessible route. The same section says portable toilet units provided for use exclusively by construction personnel on a construction site shall not be required to comply with 213 or to be on an accessible route.
Section 213.2 Exception 3 is the rule for clustered portable toilets when that construction exception does not apply: no more than 5 percent at each cluster are required to meet the toilet-room technical requirements, and those units are identified with the International Symbol of Accessibility. The Access Board’s toilet-room guide describes the practical reading as at least 5 percent in each cluster, and it repeats that construction-personnel units on a construction site are exempt.
If a trailer office, a public open house, or a delivery driver who is not part of the construction crew will use the same units, do not assume 203.2 covers every toilet on the lot. Ask the person who owns the safety plan to read those two sections against who is actually allowed on site.
What to put on the rental order
Crew size at peak, not the average. How long the units stay. Whether the crew is mobile and truly has toilets they can reach. Whether anyone is applying coatings or chemicals. Where the truck can park. Whether you need a lift-eye or a caged unit for a high-rise. A service day of the week, and a phone number that answers when a unit is unusable on a Wednesday. The city pages list companies that publish a yard and a phone. Call two. Compare the service line, not a star rating this site does not have.